1000W 20khz LCD Display Portable Medical Science Ultrasonic Cell Disruptor For Industrial
2022113020453653 - 1000W 20khz LCD Display Portable Medical Science Ultrasonic Cell Disruptor For Industrial
202211302045532 - 1000W 20khz LCD Display Portable Medical Science Ultrasonic Cell Disruptor For Industrial
1/5
<< /span>
>

1000W 20khz LCD Display Portable Medical Science Ultrasonic Cell Disruptor For Industrial

​ Remember to empty super. This is very important. There is a case where the ultrasonic crusher starts to operate the air compressor without inserting the horn of the ultrasonic crusher into the sample. After a few seconds of air compressor, the noise of the ultrasonic crusher becomes larger in the future use. Keep in …

1000W 20khz LCD Display Portable Medical Science Ultrasonic Cell Disruptor For Industrial

  1. Remember to empty super. This is very important. There is a case where the ultrasonic crusher starts to operate the air compressor without inserting the horn of the ultrasonic crusher into the sample. After a few seconds of air compressor, the noise of the ultrasonic crusher becomes larger in the future use. Keep in mind that the longer the ultrasonic crusher lasts, the greater the damage to the instrument.
  2. The water depth of the horn (ultrasonic probe) of the ultrasonic crusher: about 1.5Cm, the liquid level height should preferably be more than 30mm, and the probe should be in the middle and not stick to the wall. Ultrasonic wave is a vertical longitudinal wave. It is not easy to form convection when it is inserted too deep, which affects the crushing efficiency.
  3. Ultrasonic crushing parameter equipment: Please refer to the user manual for this point, and set the working parameters of the instrument, mainly the parameters of time, ultrasonic power, and container selection.

Time requirements: the ultrasonic time shall not be too long each time, preferably not more than 5 seconds, and the interval time shall be greater than or equal to the ultrasonic time, which is good for heat emission.

Power requirements: it should not be too large, which may cause the sample to splash or form foam. Container selection: the number of samples is determined by the size of beaker, which is also conducive to the convection of samples in ultrasound and improves the crushing efficiency.

  1. During daily maintenance, wipe the probe with alcohol or use water for ultrasound after use
TypePower (w)Output AmplitudeAvailable Converter
PU-100UP1001/8″3/16″1/4″100ul~80ml    1%~99%
PU-150UP1501/8″3/16″1/4″100ul~100ml  1%~99%
PU-250UP2501/8″3/16″1/4″100ul~200ml   1%~99%
PU-500UP5001/8″3/16″1/4″1/2″250ul~500ml   1%~99%
PU-800UP8001/8″3/16″1/4″1/2″3/4″250ul~800ml   1%~99%