50*20*5mm PZT-8 Piezoelectric Ceramic Ring For 2000W 20khz/15khz High Power Ultrasonic Transducer
When voltage acts on piezoelectric ceramics, mechanical deformation will occur with the change of voltage and frequency. On the other hand, when piezoelectric ceramics are vibrated, an electric charge will be generated. Using this principle, when an electrical signal is applied to a vibrator composed of two piezoelec…
50*20*5mm PZT-8 Piezoelectric Ceramic Ring For 2000W 20khz/15khz High Power Ultrasonic Transducer
When voltage acts on piezoelectric ceramics, mechanical deformation will occur with the change of voltage and frequency. On the other hand, when piezoelectric ceramics are vibrated, an electric charge will be generated. Using this principle, when an electrical signal is applied to a vibrator composed of two piezoelectric ceramics or a piezoelectric ceramic and a metal plate, called a double piezoelectric chip element, ultrasonic waves will be emitted due to bending vibration. On the contrary, when ultrasonic vibration is applied to a dual piezoelectric chip element, an electrical signal will be generated. Based on the above functions, piezoelectric ceramics can be used as ultrasonic sensors.
spec | Dimension (mm) | Radial frequency (KHz) | Capacitance (pf) | Dielectric dissipation factor tanδ(%) | Electromechanical coupling coefficient (Kr) | Impedance Zr(Ω) | Thickness frequency (KHz) |
PU-PC25103 | Φ25×Φ10×3 | 66.4 | 1240±12.5% | ≤0.3 | ≥0.46 | ≤15 | 683±5% |
PU-PC225104 | Φ25×Φ10×4 | 66.4 | 930±12.5% | ≤0.3 | ≥0.46 | ≤15 | 512±5% |
PU-PC40155 | Φ40×Φ12×5 | 45.9 | 2070±12.5% | ≤0.3 | ≥0.46 | ≤15 | 410±5% |
PU-PC40155 | Φ40×Φ15×5 | 42.2 | 1960±12.5% | ≤0.3 | ≥0.46 | ≤15 | 323±5% |
PU-PC40176 | Φ40×Φ17×6 | 40.5 | 1555±12.5% | ≤0.3 | ≥0.46 | ≤15 | 341±5% |
PU-PC40205 | Φ40×Φ20×5 | 37.9 | 1700±12.5% | ≤0.3 | ≥0.47 | ≤15 | 410±5% |
PU-PC50206 | Φ50×Φ20×6 | 33.2 | 2490±12.5% | ≤0.3 | ≥0.46 | ≤15 | 341±5% |
PU-PC501765 | Φ50×Φ17×6.5 | 34.8 | 2430±12.5% | ≤0.3 | ≥0.46 | ≤15 | 315±5% |
PU-PC50236 | Φ50×Φ23×6 | 31.2 | 2340±12.5% | ≤0.3 | ≥0.47 | ≤15 | 341±5% |
PU-PC50276 | Φ50×Φ27×6 | 29.3 | 2100±12.5% | ≤0.3 | ≥0.47 | ≤15 | 341±5% |
PU-PC603010 | Φ60×Φ30×10 | 25.3 | 1922±12.5% | ≤0.3 | ≥0.47 | ≤18 | 205±5% |
50*20*5mm PZT-8 Piezoelectric Ceramic Ring For 2000W 20khz/15khz High Power Ultrasonic Transducer
标签:20khz/15khz High Power Ultrasonic Transducer, 50*20*5mm PZT-8 Piezoelectric Ceramic Ring, High power ultrasonic transducer, Piezoelectric Ceramic Ring, piezoelectric ceramics
Send Inquiry
- 50x17x6.5mm Piezoceramic Rings Piezoelectric Elements PZT82 Material For Ultrasonic Welding Transducer
- Ultrasonic Welding Mask Machine Piezo Ceramic Ring 60*30*10mm Ultrasonic Transducer Piezoelectric Ceramic Ring
- 50x17x6.5mm PZT-8 Piezoelectric Ceramic Ring For 20khz 15khz 2600W Ultrasonic Welder Transducer
- Piezoelectric Ceramic Material PZT4 PZT5 PZT8 Tube Disc Ring Piezo Ceramic
- 50*20*5mm PZT-8 Piezoelectric Ceramic Ring For 2000W 20khz/15khz High Power Ultrasonic Transducer
- 50x17x6.5mm Piezoelectric Element Piezo Ceramic Ring Piezo Element Piezoelectric Ceramic Ring For Ultrasonic Cleaner Piezo
- 50x17x6.5mm PZT-8 Piezoelectric Ceramic Ring For 20khz 15khz 2600W Ultrasonic Welder Transducer
- 10×5*x2mm PZT8 Piezo Ceramic for Tooth Cleaning Ultrasonic Beauty Transducer
- 38.1*12.75*6.35mm Pzt4 Material Ultrasonic Ceramic Piezo Element For Ultrasonic Sensor
- PZT8 Piezo Disk Element Discs Cleaning Welding Piezoelectric Ceramic Chip Ring
- 45*15*5mm PZT-8/PZT-4 Piezoelectric Ceramic Ring 28khz/35khz 800W Ultrasonic Welding Transducer With Booster
- 10x5x2mm PZT-8/PZT-4 Piezoelectric Ceramic Ring For 33khz 50W Medical Teeth Cleaning Ultrasonic Transducer