135KHZ Pzt-4 High Frequency Langevin Ultrasonic Piezoelectric Cleaning Transducer For Ultrasonic Cleaner

​ As the core component of the ultrasonic equipment, the selection of ultrasonic transducer’s characteristic parameters determines the performance of the entire equipment. Proper selection of ultrasonic transducer can make your measurement more accurate. Today, let’s talk about how to select ultrasonic tran…

135KHZ Pzt-4 High Frequency Langevin Ultrasonic Piezoelectric Cleaning Transducer For Ultrasonic Cleaner

As the core component of the ultrasonic equipment, the selection of ultrasonic transducer’s characteristic parameters determines the performance of the entire equipment. Proper selection of ultrasonic transducer can make your measurement more accurate. Today, let’s talk about how to select ultrasonic transducer?

  1. Understand the purpose of ultrasonic equipment

Know your own needs, understand the use of ultrasonic equipment, and understand the characteristics of the required ultrasonic transducer: such as the size of the range, whether it is anti-corrosion, explosion-proof.

Ultrasonic debridement transducer

  1. Select the frequency of ultrasonic transducer

The frequency of ultrasound affects its propagation, and different ultrasonic equipment has different frequency requirements. When used for flow measurement, the frequency is generally between 0.5MHZ and 2MHz. The higher the frequency of ultrasound, the more concentrated the energy and the better the directionality. However, the higher the frequency, the greater the attenuation of ultrasound.

  1. Select the incidence angle of ultrasonic transducer

The incidence angle determines the installation position of the ultrasonic transducer. In order to ensure the selectivity of the probe in receiving signals, the incidence angle should be greater than the first frontage angle and less than the second critical plane angle. The angle of one should be between 28.7 ° and 60 °.

TypeLength(mm)Weight(g)Frequency(KHz)Resonance Impedance
(Ω)
Static Capacity
(pF)±10%
Input Power(W)
PLS-QXHNQ20100949002010-205200100
PLS-QXHNQ25100777102510-206600100
PLS-QXHNQ28100666242810-206600100
PLS-QXHNQ2560775302510-20540060
PLS-QXHNQ2860684702810-20380060
PLS-QXHNQ2850824252810-20410050
PLS-QXHNQ3360584203310-20380060
PLS-QXHNQ4060563104010-20540060
PLS-QXHNQ4050573004010-20410050
PLS-QXHNQ5435361355410-20320035
PLS-QXHNQ6860804606810-20380060
PLS-QXHNQ68120675886810-207800120
PLS-QXHNQ8060603258010-20540060
PLS-QXHNQ120605626012010-20540060
PLS-QXHNQ135505421513510-20420050

135KHZ Pzt-4 High Frequency Langevin Ultrasonic Piezoelectric Cleaning Transducer For Ultrasonic Cleaner