Call Us: 0757-29363805Email: admin@pulisonic.com
120KHZ High Frequency Ultrasound Transducer For Industrial Ultrasonic Cleaning Machine
2023041216130371 - 120KHZ High Frequency Ultrasound Transducer For Industrial Ultrasonic Cleaning Machine
2023041216131344 - 120KHZ High Frequency Ultrasound Transducer For Industrial Ultrasonic Cleaning Machine
1/5
<< /span>
>

120KHZ High Frequency Ultrasound Transducer For Industrial Ultrasonic Cleaning Machine

​ Analyze the performance parameters of ultrasonic transducer, which is an energy converter, and its performance description and evaluation need many parameters. The characteristic parameters of ultrasonic transducer include resonance frequency, bandwidth, electromechanical coupling coefficient, electroacoustic efficie…

120KHZ High Frequency Ultrasound Transducer For Industrial Ultrasonic Cleaning Machine

Analyze the performance parameters of ultrasonic transducer, which is an energy converter, and its performance description and evaluation need many parameters. The characteristic parameters of ultrasonic transducer include resonance frequency, bandwidth, electromechanical coupling coefficient, electroacoustic efficiency, and mechanical quality factor

Analyze the performance parameters of ultrasonic transducer, which is an energy converter, and its performance description and evaluation need many parameters. The characteristic parameters of ultrasonic transducer include resonance frequency, bandwidth, electromechanical coupling coefficient, electroacoustic efficiency, mechanical quality factor, impedance characteristics, frequency characteristics, directivity, transmission and reception sensitivity, etc. Different types of transducers have different requirements for performance parameters. For example, for emission type ultrasonic transducers, high output power and high energy conversion efficiency are required; For receiving type ultrasonic transducers, wide frequency bands, high sensitivity and resolution are required. Therefore, in the specific design process of the transducer, it is necessary to design the relevant parameters of the transducer reasonably based on the specific application.

TypeLength(mm)Weight(g)Frequency(KHz)Resonance Impedance
(Ω)
Static Capacity
(pF)±10%
Input Power(W)
PLS-QXHNQ20100949002010-205200100
PLS-QXHNQ25100777102510-206600100
PLS-QXHNQ28100666242810-206600100
PLS-QXHNQ2560775302510-20540060
PLS-QXHNQ2860684702810-20380060
PLS-QXHNQ2850824252810-20410050
PLS-QXHNQ3360584203310-20380060
PLS-QXHNQ4060563104010-20540060
PLS-QXHNQ4050573004010-20410050
PLS-QXHNQ5435361355410-20320035
PLS-QXHNQ6860804606810-20380060
PLS-QXHNQ68120675886810-207800120
PLS-QXHNQ8060603258010-20540060
PLS-QXHNQ120605626012010-20540060
PLS-QXHNQ135505421513510-20420050

120KHZ High Frequency Ultrasound Transducer For Industrial Ultrasonic Cleaning Machine

标签:, ,

Send Inquiry